BEGIN:VCALENDAR
VERSION:2.0
PRODID:-// - ECPv6.18.3//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://competad.com
X-WR-CALDESC:Events for 
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Shanghai
BEGIN:STANDARD
TZOFFSETFROM:+0800
TZOFFSETTO:+0800
TZNAME:CST
DTSTART:20180101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Shanghai:20190816T083000
DTEND;TZID=Asia/Shanghai:20190817T173000
DTSTAMP:20190423T012336Z
CREATED:20190306T204149Z
LAST-MODIFIED:20190423T012336Z
UID:1403-1565944200-1566063000@competad.com
SUMMARY:Power Quality Analysis and Harmonics  Technical\, Theoretical and Hands On Training
DESCRIPTION:Click here to REGISTER \nCOURSE DURATION: 2 Days Training\, 16 – hours Session\n This practical course provides you with methods and procedures used internationally in evaluating obtained data Power Quality Analysis (PQA). This course will equip attendees with the knowledge on different Power Quality Disturbances that affects most sensitive equipment in electrical system and how to mitigate them. Moreover\,harmonics mitigation will be an important subject as it creates unwanted energy that distort nominal power requirements of the system. Correct PQA meter installation and evaluation will then also be very essential in gathering needed data for the detection of problems \nNow with the engineers having the knowledge in PQA\,will formulate a way to deal with these problems to assess and safely maintain electrical systems in their respective fields. \nOBJECTIVES:\n At the end of the program\, the participants will be able to:\n      A. How\, when and where to use a power quality analyzer\, know power quality monitoring techniques\n      B. Identify different power quality disturbances\n      C. Origin and effects of power quality disturbances\n      D. Specify solutions to mitigate every power quality disturbances\n      E. Knowledge in Harmonics and Noise\n      F. Basic design of harmonic filters and specifying the transformer K factor rating \nWHO SHOULD ATTEND:\n This course will enhance the understanding and increase competencies for:\n      A. Electrical Engineers\n      B. Engineering department staffs\n      C. Test engineers and Technicians\n      D. Cadet engineers\n      E. Substation\, Facility and Maintenance engineers \nCOURSE OUTLINE:\n IEEE STANDARDS AND LOCAL CODES SUCH AS PHILIPPINE GRID AND DISTRIBUTION CODES \nDAY 1 -8 hours \nI. FUNDAMENTALS:\n      A. Introduction\n      B. What is Power Quality?\n      C. Effects of Poor Power Quality\n      D. Electromagnetic Compatibility (IEC Standards)\n      E. Local Power Quality Standards\n      F. Power Quality Disturbances \nII. POWER QUALITY DISTURBANCES\n      A. Impulsive Transient\n      B. Oscillatory Transient\n      C. Overvoltage\n      D. Undervoltage\n      E. Sustained Power Interruption\n      F. Momentary Power Interruption\n      G. Short Duration Power Interruption\n      H. Voltage Sag\n      I Voltage Swell\n      J. Voltage Imbalance\n      K. Voltage Fluctuation\n      L. Harmonic Distortion\n      M. Voltage Variation Computation\n      N. Voltage Unbalance Computation\n      O. Activity: Computations and Short Review of Discussed items \nIII. SOLUTION TO POWER QUALITY PROBLEMS\n      A. Motor Generator Sets\n      B. Uninterruptible Power Supply (UPS)\n      C. Ferroresonant Transformers Or Constant Voltage Transformer\n      D. Dynamic Voltage Restorer\n      E. Static VAR Compensator\n      F. Isolation Transformers and Reactors (chokes)\n      G. Transient Voltage Surge Suppressor (TVSS)\n      H. Line Voltage Regulators\n      I. Harmonic Filters\n      J. Electroflow\n      K. Lightning Protection\n      L. Surge Protection\n      M. Power Quality Meter\n      N. Power Quality Analyzer \nIV. POWER SYSTEM HARMONICS\n      A. Introduction\n      B. Definition of Terms\n      C. Sources of Harmonic Currents\n      D. Effects of Harmonics\n      E. System Response Characteristics\n      F. Resonance Conditions\n      G. Control of Harmonic Currents\n      H. Analysis Methods\n      I. Design of Harmonic Filter\n      J. Derating of Power Equipment\n      K. Power Failures Due to Harmonics\n      L. K Factor Rating of Transformer\n      M. Special Topic\n           i. High Frequency Harmonics / Noise as per IEEE 1100\n           ii. Effects of Noise\n           iii. Mitigation of Noise in Electrical System\n      N. Activity: Computations and Short Review of Discussed items \nDAY 2 – 8 hours \nV. POWER QUALITY ANALYSIS (PQA) AND HARMONICS HANDS-ON PREPARATION\n     A . Activity: Review of theoretical knowledge and application to hands on.\n      B. Safety in conducting PQA measurements\n           i. Use of appropriate Personal Protective Equipment (PPE)\n           ii. Standard safety practices\n      C. Threshold limits as according to international standard guidelines (IEEE standards)\n      D. Familiarization of PQA accessories and how to use them\n      E. Hardware set-up of power quality analyzers or meters\n      F. Software set-up of power qual ity analyzers \nIV. POWER QUALITY ANALYSIS (PQA) AND HARMONICS HANDS-ON\n      A. Group activity: Actual installation of PQA device on live circuit\n      B. Gathering and downloading data to a computer\n      C. Group activity: Evaluation of obtained data as per guidelines\n      D. Group activity: Writing a technical report and recommendations\n      E. Discussions on technical reports\n      F. Case studies\n      G. Question and Answer\n \nRegistration Instructions:  \n1. Fill out the registration form by clicking here.\n2. You may also download the word attachment in the link and send it to training@competad.com\n3. Our admin team shall send you shortly the Statement of Account/Confirmation of registration. Sign the statement of account to conform and finalize your registration.\n4. Follow the instructions in the statement of account and complete your learning investment deposit.\n5. Send the scanned copy of the signed Statement of Account and your deposit slip.\n6. Should you need an official Billing Invoice\, please call us at (02)4333342.
URL:https://competad.com/event/power-quality-analysis-and-harmonics-technical-theoretical-and-hands-on-training-2/
LOCATION:Marsk Training Room\, Marsk Building\, Aurora Boulevard corner Balete Drive\, Quezon City\, NCR\, 1111\, Philippines
CATEGORIES:Public Training
ORGANIZER;CN="COMPETAD Training and Professional Development Services":MAILTO:publictraining@competad.com
END:VEVENT
END:VCALENDAR