BEGIN:VCALENDAR
VERSION:2.0
PRODID:-// - ECPv6.18.3.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://competad.com
X-WR-CALDESC:Events for 
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Asia/Shanghai
BEGIN:STANDARD
TZOFFSETFROM:+0800
TZOFFSETTO:+0800
TZNAME:CST
DTSTART:20170101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Asia/Shanghai:20180907T083000
DTEND;TZID=Asia/Shanghai:20180907T173000
DTSTAMP:20180731T185802Z
CREATED:20170423T210748Z
LAST-MODIFIED:20180731T185802Z
UID:826-1536309000-1536341400@competad.com
SUMMARY:Oil - Immersed Power Transformer Maintenance: Analysis of Insulating Oils
DESCRIPTION:Click here to REGISTER \nCourse Duration: 1 day (8 hours) \n \nThis 8-hour practical course provides you with methods and procedures used internationally in evaluating data obtained on power transformer insulating oils. This course will equip attendees with the knowledge of what is happening inside the transformer up to mitigating possible severe problems that may occur in the transformer; without opening it by just utilizing test data obtained in oil laboratories. Basic information on previous technology and the current technology in insulating oils will also be discussed as to help engineers be safe at site and continue safe operation of the substation. \nThis will also be discussing condition-based maintenance done on oil-filled power transformer and the insulating oil itself. Moreover\, analyzation of the data on lab tests done in insulating oils is the focus of the course. Using correct guidelines\, analysis and recommendation is very essential to predict failure modes of the transformer. \n  \nWho should attend? \nThis course will enhance the understanding and increase competencies for: \n\nElectrical consultants that gives technical advice on maintaining substation apparatus to clients.\nEngineers & technicians in the utility\, transmission and generation sectors\, that operate and maintain oil filled power transformer in substations.\nEngineers and electricians in commercial and industrial field that maintains oil filled power transformers.\nElectrical engineering graduates who would like to be test and applications engineers and Technicians for substation.\n\nCourse Objectives: \nAt the end of the program\, the participants will be able to: \n\nHave basic knowledge about transformer insulating oils.\nKnow different characteristics of transformer insulating oils.\nHave knowledge on what tests to conduct in insulating oils.\nKnow proper sampling techniques in transformer tanks.\nInterpret laboratory data and correct present abnormalities in the system.\nKnowledge in present technologies in transformer and transformer oil maintenance.\nSafely maintain and continue good operation of oil immersed power transformer in their facilities.\n\nCourse outline: \n(4 hours in the Morning) \n\nIntroduction\n\nWhat are Insulating Oils\nOil as insulating material\nWhat are PCBs?\nHistory Insulating Oils in Power transformers\n\n\n\n  \n\nCharacteristics of Insulating Oils\n\nCommonly used Insulating Oils in Power Transformers\nMineral Oils\nNatural Esters\n\n\n\n  \n\nMaintenance on Oil Filled Power Transformer and Oil Itself\n\nDifferent types of Insulation\nProblems detected by Analysis\n\n\n\n  \n\nMineral Insulating Oils Tests (ASTM\, IEC and IEEE C57.104 Guidelines)\n\nDissolved Gas Analysis Test (DGA)\nOil quality tests (OQT)\nFuran Analysis Test\n\n\n\n  \n(4 hours in the Afternoon) \n\nMoisture in oil\n\nMoisture Types\nDifferent effects of moisture in transformers\n\n\n\n  \n\nSampling Techniques and Procedures\n\nTransformer types\nProper sampling procedures and techniques\n\n\n\n  \n\nInterpretation of Data (DGA and OQT)\n\nMost commonly used Techniques\nIEEE Guidelines C57.104\nGas Ratios\nDuval’s Triangle\nCorrective actions\n\n\n\n  \n\nNew Tests and Technologies in the Industry\n\nOnline and Offline Tests\nDielectric Response Analysis\n\n\n\n  \n\nCase Studies\n\nRegistration Instructions:  \n1. Fill out the registration form by clicking the link on top of this page. You may also download the MS Word attachment send it to training@competad.com\n2. Our admin team shall send you shortly the Statement of Account/Confirmation of registration. Sign the statement of account to conform and finalize your registration and email the soft copy.\n3. Follow the instructions in the statement of account and complete your payment.\n4. Send the scanned copy of the Statement of Account and your deposit slip.\n5. Should you need an official Billing Invoice\, please call us at (02) 4333342 or click here for alternative numbers.
URL:https://competad.com/event/transformer-insulating-oil-analysis-fundamentals/
LOCATION:Marsk Training Room\, Marsk Building\, Aurora Boulevard corner Balete Drive\, Quezon City\, NCR\, 1111\, Philippines
CATEGORIES:Public Training
ORGANIZER;CN="COMPETAD Training and Professional Development Services":MAILTO:publictraining@competad.com
END:VEVENT
END:VCALENDAR